SATEL VERSA 59
AMD-100 / AMD-101 magnetic contact
1. Enter a number from the 0 to 50 range to define the rules of device presence control, and
then press .
2. Press any numeric key to define whether the detector is to be always active ( – no, –
yes), and then press .
3. Use the and keys to select which of the two reed switches (bottom or side) of
the magnetic contact is to be active, and then press .
AMD-102 magnetic contact
Having selected the first of the zones to which the detector is assigned:
1. Enter a number from the 0 to 50 range to define the rules of device presence control, and
then press .
2. Press any numeric key to define whether the detector is to be always active ( – no, –
yes), and then press .
3. Use the
and keys to select which of the two reed switches (bottom or side) of
the magnetic contact is to be active, and then press
.
Having selected the second of the zones to which the detector is assigned:
1. Enter a digit from the 1 to 8 range to define the number of pulses that will trigger alarm,
and then press .
2. Use the and keys to select the pulse validity time (30, 120 or 240 seconds or
unlimited time), and then press .
AOCD-250 detector
1. Enter a number from the 0 to 50 range to define the rules of device presence control, and
then press .
2. Press any numeric key to define whether the detector is to be always active ( – no, –
yes), and then press .
3. Enter a digit from the 1 do 4 range to define sensitivity of the PIR sensor (1 – minimum; 4
– maximum), and then press
.
4. Enter a digit from the 1 do 8 range to define sensitivity of the microwave sensor (1 –
minimum; 8 – maximum), and then press
.
AOD-200 detector
1. Enter a number from the 0 to 50 range to define the rules of device presence control, and
then press .
2. Press any numeric key to define whether the detector is to be always active ( – no, –
yes), and then press .
3. Enter a digit from the 1 do 4 range to define sensitivity of the PIR sensor (1 – minimum; 4
– maximum), and then press .
4. Enter a digit from the 1 do 8 range to define sensitivity of the microwave sensor (1 –
minimum; 8 – maximum), and then press .
5. Enter a digit from the 1 do 4 range to define sensitivity of the dusk sensor (1 – minimum; 4
– maximum), and then press .
APMD-150 detector
6. Enter a number from the 0 to 50 range to define the rules of device presence control, and
then press .