5 Cleaning and Performing Printer Adjustments
182
S84-ex/S86-ex Operator Manual
5.3.5
Limitation on Base Reference Point Adjustment
After adjusting the print position and the stop position, the distance between these two positions should
not exceed one pitch size (including liner) of the media.
Refer to the figure and table below for the adjustment range of the distance between the print position
and the stop position for options.
Adjustment range of the distance between the print position and the stop position for options:
Types of Options
Adjusted Distance
(Min.)
Initial Distance
Adjusted Distance
(Max.)
Dispenser 7.5 mm (0.3”) 15.0 mm (0.6”) 22.5 mm (0.9”)