Adjusting the Gap Sensor Level Manually
The adjustment procedure for the Gap sensor level is as follows:
1 Go to the SENSOR LEVEL setting screen
of SERVICE MODE.
Perform steps 1 through 4 of Section 5.5.1
Adjusting the Media Sensor Automatically.
2 Select MANUAL using the / buttons
and then press the ENTER button.
SENSOR SELECT shows on the screen.
3 Press the / buttons to select GAP and
then press the ENTER button.
The light emission level adjustment of the Gap
sensor is shown.
4 On the SENSOR LEVEL GAP(E) screen,
press the / buttons to set ADJUST
LEVEL to 2 and then press the ENTER
button.
The adjustment range of ADJUST LEVEL is from 0
to 3.
We recommend using the initial value which is 2.
The light reception level adjustment of the Gap
sensor is shown.
First, adjust the “Low” reception level (voltage) of the Gap sensor.
5 Open the top cover and unlock the media
feed and media sensor assembly .
6 Physically place the liner without the
label resting over the Gap sensor.
7 Press the media feed and media sensor
assembly down to lock it.
To get the correct adjustment result, close the
media sensor assembly before performing the
adjustment.