5 Cleaning and Performing Printer Adjustments
194
S84-ex/S86-ex Operator Manual
Next, check the I-MARK(R) value (voltage) of the Paper end (I-mark) sensor when no
media is placed on the sensor.
6 Unlock the media feed and media sensor
assembly .
7 Remove all the media from the media
sensor.
8 Press the media feed and media sensor
assembly down to lock it.
To get the correct adjustment result, close the
media sensor assembly before performing the
adjustment.
9
Check if the new I-MARK(R) value is 2.2 V
or higher.
If not, change ADJUST LEVEL using the /
buttons until the I-MARK(R) value is 2.2 V or higher.
10
Press the ENTER button to confirm the setting and proceed to the next adjustment
screen.
Criteria for Adjustment:
I-MARK(R) value (liner without label): +2.0 V
I-MARK(R) value (without any media): +2.2 V
1
I-mark sensor
I-MARK(R) level +2.2V