6 Troubleshooting
202
S84-ex/S86-ex Operator Manual
03
Parity error
Flashes blue and red
alternately.
Three short beeps.
To clear the error:
Power off the printer.
RS-232C settings are
incorrect.
Adjust the interface
settings correctly.
The cable connection is
incorrect.
Check and connect the
cable correctly.
04
Overrun error
Flashes blue and red
alternately.
Three short beeps.
To clear the error:
Power off the printer.
RS-232C settings are
incorrect.
Adjust the interface
settings correctly.
The cable connection is
incorrect.
Check and connect the
cable correctly.
05
Framing error
Flashes blue and red
alternately.
Three short beeps.
To clear the error:
Power off the printer.
RS-232C settings are
incorrect.
Adjust the interface
settings correctly.
The cable connection is
incorrect.
Check and connect the
cable correctly.
06
Buffer overflow
Flashes blue and red
alternately.
Three short beeps.
To clear the error:
Power off the printer.
The size of the received
data exceeds the size of
the receive buffer.
Do not send data that
exceeds the size of the
receive buffer.
The communication
settings between the
printer and the host are
incorrect.
Set the communication
between the printer and
the host correctly.
Error
No.
Message LED/Buzzer Cause Countermeasure