Startup operation
BV-H2464GB, 1234
- 48 -
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
5. The containers or vehicles in which the material is transported onto a (legal-for-trade) commercial scales
must be cleaned and re-weighed (tared) before each filling. The commercial scales must be sufficiently
accurate to measure the quantity MW.
The new value P04.02
new
is calculated from the old value P04.02
old
using the counter progression MA from
the continuous measurement and the mass MW calculated from the control scales as follows:
P04.02
new
= P04.02
old
* MW / MA
For example:
Old value of P04.02 = 1
A material quantity of MW = 4.9 t is conveyed over a period of 15 minutes. The counter progression MA
read off the device is 5.0 t.
P04.02
new
= 1 * 4.9/5.0 = 0.98
The calculated value should be entered into P04.02.