Parameters
INTECONT® Tersus Belt weigher, Instruction Manual
Schenck Process Group
BV-H2464GB, 1234
- 49 -
13
1313
13
Parameters
ParametersParameters
Parameters
The INTECONT Tersus is adapted to each application by means of parameters. No special programing
knowledge is therefore necessary.
Fig. 8: Parameter sets
Preparation and Alteration
Active parameters set
A summary of the effec-
tive parameters
Always active via EasyServe or on the unit
Factory settings
Complete parameters set
Non-alterable basic set-
ting
Use EasyServe or the unit
to copy into the active pa-
rameter set
Cannot be changed
Backup set
Pre-setting for a group of
applications or a setting
stored during commis-
sioning
Use EasyServe or the unit
to copy into the active pa-
rameter set
Only using EasyServe in
expert mode
Tab. 1 : Using parameter sets
Note: Parameters not required for an application can be faded out or declared 'read only' using EasyServe
in expert mode. EasyServe compiles a list of visible parameters that form an integral part of the system do-
cumentation. Together with the operating manual they make up the relevant control system documentation
for an application. The parameter list contained in the operating manual contains all of the parameters re-
gardless of their actual use in an application.
In addition to the parameter set stored in the scales, we recommend that after commissioning you keep a
copy of the parameter set in a mass storage medium using EasyServe.
The parameters are arranged into blocks to for clarity. A parameter is uniquely identified by its block and
number within that block in the respective scales software version, e.g. 'P01.03' means 'parameter block 1,
parameter no.3'.
Notes:
▪ Gaps can appear between block numbers and parameters within the blocks. In rare cases, the number
of a parameter may change.