EasyManua.ls Logo

Schenck Vibrocontrol 110 C01 - Technical Data; Supply Voltage; Fuses

Schenck Vibrocontrol 110 C01
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VC 1100 Technical Data
VC1100E/tedata Version 2
© Schenck VIBRO GmbH, D-64273 Darmstadt, November 97 C01 / C02 - C11 / C12 2-1
2 Technical Data
Supply Voltage
Type VC-1100-C01
Type VC-1100-C11 115 V AC or
230 V AC +15 % / -25 %
jumper selectable
48 ... 400 Hz
Power consumption approx. 15 VA
Type VC-1100-C02
Type VC-1100-C12 24 V DC (16 ... 36 V)
Power consumption approx. 15 W
Fuses
Supply Voltage 115/230 V AC 2 Thermo-Resistors
250 °F (125 °C)
built-in the primary
transformer windings
Supply Voltage 24 V DC NTC - Resistor
Transducer supply -24 V 2 x 30 mA short-circuit-
proof
EMC Emitted interference according to EN 50081-1
Immunitity from interferences according to EN 50082-2