VC 1100 Built-in Operating Panel and Display
VC1100E/bult-in Version 2
© Schenck VIBRO GmbH, D-64273 Darmstadt, November 97 C01 / C02 - C11 / C12 4-17
Unit errors
Format: ER -nn is a number with 1 to 5 digits
Example: < ER -1<
Error
code
see page 20 Meaning
-1 ! Error in operating system
-2 ! Error in operating system
-3 ! Error in operating system
-4 ! Error in operating system
-6 !
power down (last message,
if time is sufficient)
-8 r
Program monitoring is out of
operation or defective.
-31 r
Disrupted calibration data
(run auto-calibration!)
-32 ! Error EEPROM / Hardware error
-33 ! Error ROM / Hardware error
-34 ! Error RAM / Hardware error
-35 !
Disrupted data in RAM /
Hardware error
-36 k
Auto-calibration not successful /
Hardware error
-37 e/r
e) No valid configuration stored
in EEPROM.
(Re-configure) / Hardware
error
r) If no valid configuration can
be made, a hardware error is
present.