EasyManua.ls Logo

Schenck Vibrocontrol 110 C01 - Filters; Signal Conditioning and Signal Detection Type

Schenck Vibrocontrol 110 C01
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Overview VC 1100
Version 2 overview//VC1100E
1-6 C01 / C02 - C11 / C12 © Schenck VIBRO GmbH, D-64273 Darmstadt, November 97
Filters
Machine vibrations are sensed by the vibration velocity trans-
ducers or accelerometers. Which pickup to use depends on the
application. The following table lists the filters that may be used
with the different measured parameters and pickup types:
Measured Parameter Transducer Filter
v a
Vibration displacement x 10 Hz ... 1000 Hz
Vibration Velocity x x 1 Hz ... 1000 Hz
x x 3 Hz ... 1000 Hz
x x 10 Hz ... 1000 Hz
x 10 Hz ... 10 kHz
Vibration Acceleration x 3 Hz ... 1000 Hz
x 10 Hz ... 1000 Hz
x 3 Hz ... 10 kHz
10 Hz ... 10 kHz
Bearing Condition x 15 Hz ... 50 kHz
Transducer : v = Vibration Velocity Transducer
a = Accelerometer
* ) Fulfills the requirements of International Standard ISO 2372
Signal Conditioning and Signal Detection Type
The built-in signal conditioners are microprocessor controlled.
Gain factors, filters, and the integrator are set automatically. The
settings are determined by the microprocessor from the
configuration.

Table of Contents