Technical Data VC 1100
Version 2 → tedata/VC1100E
2-4 C01 / C02 - C11 / C12 © Schenck VIBRO GmbH, D-64273 Darmstadt, November 97
• Vibration Velocity: 1... 1000 Hz (v-or a-pickup)
or 3... 1000 Hz (v-or a-pickup)
or 10... 1000 Hz (v-or a-pickup)
or 10...10000 Hz ( a-pickup)
• Vibration Acceleration: 3... 1000 Hz (a-pickup)
or 10... 1000 Hz (a-pickup)
or 3...10000 Hz (a-pickup)
or 10...10000 Hz (a-pickup)
• Bearing Condition: 13 kHz ... 64 kHz- 3 dB (a-pickup)
Measured Parameters and Signal Detection Type
3)
• Root-Mean-Square-Value Xrms or X
eff
for s/v/a
• Zero-to-Peak-Value X
pc
for s/v/a
• Peak-to-Peak-Value X
ppc
for s/v/a
• Bearing Condition BCU
3) The respective selection is made software-controlled in dialog mode.
4) Ranges between min. and max. are infinitely variable.