VC 1100 Technical Data
VC1100E/tedata Version 2 →
© Schenck VIBRO GmbH, D-64273 Darmstadt, November 97 C01 / C02 - C11 / C12 2-7
Microprocessor - System
Storage capacity
RAM 8 kByte
EPROM 64 kByte
EEPROM 2 kByte
Built-in Operator Panel
• 5 push buttons
• LCD, 16 characters, alphanumeric
Storage of setup parameters in non-volatile EEPROM
Limit values
3)
• Total number 6 (3 per channel)
• per channel 1 limit value 1 (lim_1)
1 limit value 2 (lim_2)
1 limit value Bearing Condition (lim_b)
Relays
• Self-Monitoring 1 OK-Relay to indicate malfunctions detected by
the self-monitoring function
• Alarm Level Exceedances 3 Relays K1, K2, K3 to indicate alarm level
exceedances
3)
• Range of settings for limit values 10 ... 100 % of the corresponding measuring range
• Contacts 2 pole
• Contact Rating 250 V AC, 5 A (Ohm Load, cos ϕ = 1)
250 V AC, 2 A (Inductive Load, cos ϕ = 0.4 ... 0.7)
24 V DC / 0.4 A
48 V DC / 0.2 A
A spark extinguisher must be installed as close to the spark
generator as possible !
3) The respective selection is made software-controlled in dialog mode.