EasyManua.ls Logo

Schenck Vibrocontrol 110 C01 - Page 24

Schenck Vibrocontrol 110 C01
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Technical Data VC 1100
Version 2 tedata/VC1100E
2-6 C01 / C02 - C11 / C12 © Schenck VIBRO GmbH, D-64273 Darmstadt, November 97
Dual-Channel-Mode
Vibration Parameters
Measuring Time per Channel: 3.0 s
Settling Times:
Filter with a lower frequency corner of 1 Hz 1.75 s
Filter with a lower frequency corner of 3 Hz 1.0 s
ISO-Filter with a lower frequency corner of 10 Hz 1.25 s
Special Filter 1.75 s
Integrator 6.0 s
Linearization Circuit 5.75 s
Bearing Condition
Measuring Time per Channel: 1.25 s
Setting Time 2.75 s
Analog Output
Number of Outputs 2
3)
Resolution: 256 (8 Bit)
(both outputs independently adjustable)
Refresh time ca. alle 0.5 s
0...10 V DC R
load
500
(withstands short circuits)
or 0...20 mA Load 500
or 4...20 mA Load 500
Error: U-Output
± 1 % of measured value ± 0.1 mV
I-Output
± 2 % of measured value ± 0.2 µA
Buffered Outputs
Number of Outputs 2 Output of the pickup signal of each
channel with the correct phase. The
signal is attenuated by a factor of 0.1
Source impedance : 0
Max. output current : 4 mA
Resistance : > 10 k
Max. cable length with cable
capacitance of 70 pF/m
(Wire against wire) : 16 m
3) The respective selection is made software-controlled in dialog mode.

Table of Contents