Technical Data VC 1100
Version 2 → tedata/VC1100E
2-6 C01 / C02 - C11 / C12 © Schenck VIBRO GmbH, D-64273 Darmstadt, November 97
♦ Dual-Channel-Mode
• Vibration Parameters
Measuring Time per Channel: 3.0 s
Settling Times:
Filter with a lower frequency corner of 1 Hz 1.75 s
Filter with a lower frequency corner of 3 Hz 1.0 s
ISO-Filter with a lower frequency corner of 10 Hz 1.25 s
Special Filter 1.75 s
Integrator 6.0 s
Linearization Circuit 5.75 s
• Bearing Condition
Measuring Time per Channel: 1.25 s
Setting Time 2.75 s
♦ Analog Output
• Number of Outputs 2
3)
Resolution: 256 (8 Bit)
(both outputs independently adjustable)
Refresh time ca. alle 0.5 s
0...10 V DC R
load
≥ 500 Ω
(withstands short circuits)
or 0...20 mA Load ≤ 500 Ω
or 4...20 mA Load ≤ 500 Ω
Error: U-Output
± 1 % of measured value ± 0.1 mV
I-Output
± 2 % of measured value ± 0.2 µA
• Buffered Outputs
Number of Outputs 2 Output of the pickup signal of each
channel with the correct phase. The
signal is attenuated by a factor of 0.1
Source impedance : ≈ 0 Ω
Max. output current : 4 mA
Resistance : > 10 kΩ
Max. cable length with cable
capacitance of 70 pF/m
(Wire against wire) : ≤ 16 m
3) The respective selection is made software-controlled in dialog mode.