Installation manual
HB-37420-810-01-25F-EN PSC1-C-100 Installation manual - V2.2.docx Page 172 of 201
Version: 38F
Risk assessment according to EN ISO 13849-1
S – severity of injury
S1 = slight, reversible injury
S2 = serious, irreversible injury
F – frequency and/or exposure to hazard
F1= seldom, not cyclic
F2 = frequent to continuous and/or exposure
time is long, cyclic operation
P – possibility of avoiding hazard
P1 = possible, slow movement / acceleration
P2 = scarcely possible, high acceleration in
event of a fault
Risk assessment according to EN ISO 61508
a
1
2
3
4
b
W
3
---
a
1
2
3
4
W
2
---
---
a
1
2
3
W
1
--- = keine Sicherheitsanforderung
a = Keine speziellen Sicherheitsanforderungen
b = eine einzelnes E/E/PES ist nicht ausreichend
1,2,3,4 = Sicherheits-Integritätslevel
C
A
C
B
C
C
C
D
F
A
F
B
P
A
P
B
F
A
F
B
F
A
F
B
P
A
P
B
P
A
P
B
P
A
P
B
x
1
x
2
x
4
x
3
x
5
x
6
Startpunkt
Abschätzung der
Risikominderung
C = Risikoparameter der Auswirkung
F = Risikoparameter der Häufigkeit und Aufenthaltsdauer
P = Risikoparameter der Möglichkeit, den gefährlichen Vorfall
zu vermeiden
W = Wahrscheinlichkeit des unerwünschten Ereignisses