Installation manual
HB-37420-810-01-25F-EN PSC1-C-100 Installation manual - V2.2.docx Page 187 of 201
Version: 25F
Examples for fault exclusions and measures assigned:
• Positive locking connection on mech. shaft connections
• Dimensioning based on adequate theoretical principles related to fracture of
components in the safety chain
• Positive guidance in conjunction with positive separation on sticking of switching
contacts
• Protected laying within the switchgear to avoid short-circuits in cables and wires, as
well as laying cables in cable ducts