After checking the program, the parameters are to be checked against the parameters in the
specifications by comparing.
Example SLS:
Validation report
Safely Limited Speed (SLS)
Index Parameter Value Validated
SLS
1
Selected axis:
1
Speed threshold: 200 0
SLS
2
Selected axis:
1
Speed threshold: 500 0
SLS - 3 Selected axis: 1
Speed threshold:
100
0
Acceleration threshold:
2
0
SLS
4
Selected axis:
1
Speed threshold: 50 0
SSX ramp assigned:
1
Example encoder configuration:
Validation report
Axis configuration / sensor interface
Axis 1
General parameters
Measurement length:
500
0
Type:
Rotary
Position processing: Active
Maximum speed:
2000
0
Switch off position: 10 0
Shutdown speed:
100
0
Sensors
1
2
Type: SSI standard SSI standard
Format:
Binary
Binary
Count direction: high
high
Voltage supply:
24V
24V
Resolution:
1024
Steps/1000
mm
64
Steps/1000
mm
Offset: 0 Steps 0 Steps