Installation manual
HB-37420-810-01-25F-EN PSC1-C-100 Installation manual - V2.2.docx Page 57 of 201
Version: 25F
Type of
sensor /
input
element
Input Tests that can be
configured /
operative tests
Achieva
ble PL
accordi
ng to
EN ISO
Fault exclusion for
input element
Condition for input
element
Cross-circuit test
With time
monitoring
Start test
Cyclic test in
operation
Dual-
channel
serial
I00..I04
I08..I13
d
Short-circuit on the
input/signal wire
Stuck / positive opening
Connection in the switch
cabinet or protected laying
MTTF
d
= medium
O O e
Short-circuit on the
input/signal wire
Connection in the switch
cabinet or protected laying
MTTF
d
= high
All
O O d
Short-circuit on the
input/signal wire
Connection in the switch
cabinet or protected laying
MTTF
d
= medium
X O O e
MTTF
d
= high
Options:
X:
Diagnostic measure activated
O:
At least 1 diagnostic measure activated