Operation via Ethernet (Ethernet interface)
Field"MF2Functionconguration" Requirements for the display
Parameter "MF2 activation": Option "Enable"
Parameter Description
Function Select function for the multifunction MF2 output.
Read/Write access
Read and write
Input value
0: Distance / 1: Velocity / 2: Service
Factory setting
Service
Active state Select level for the active condition for the multifunction
output MF2.
Read/Write access
Read and write
Input value
0: high / 1: low
Factory setting
Low
Table 41: Page "Parameter settings" – eld "MF2 Function conguration"
Field "MF2, Threshold distance
underow"
Seepage63,Table38,"MF1,Thresholddistanceunderow"
Field "MF2, Threshold exceeded
exceeded"
See page 64, Table 39, "MF1, Threshold velocity exceeded"
Field"MF2,Serviceconguration"
Seepage64,Table40,"MF1,Serviceconguration"
Field "Number of MF activation"
Parameter Description
MF1 Counts the switching events of the multifunction input and
output MF1. You may reset the counters via the button "Reset
MF1".
Read/Write access
Read and write
Input value
–2147483648 ... 2147483647
M2 Counts the switching events of the multifunction output MF2.
You may reset the counters via the button "Reset MF2".
Read/Write access
Read and write
Input value
–2147483648 ... 2147483647
Table 42: Page "Parameter settings" – eld "Number MF activation"