Operation via Ethernet (Ethernet interface)
66 © SICK AG • Subject to change without notice • 8021823/126P/2018-12-17
Field "Advanced device functions"
Parameter Description
Averagelter
distance
Selectlterdepthforthedistancevalues.
Read/Write access
Read and write
Input value
0: fast / 1: medium / 2: slow
Factory setting
Medium
Averagelter
velocity
Selectlterdepthforthespeedvalues.
Read/Write access
Read and write
Input value
0: fast / 1: medium / 2: slow
Factory setting
Medium
Measuring
direction
Select measuring direction for the distance.
Read/write access
Read and write
Input value
[+]:positivedirection/[-]negativedirection
Factory setting
Positive direction
Error
rejection
Select time for error suppression. If there is an error, the
measurement value is indicated as "0".
Read/Write access
Read and write
Input value
0:o/1:50ms/2:200ms
Factory setting
200 ms
Table 43: Page “Parameter settings” – eld “Advanced device function”