Comments on the connections of the MSC800-0000 logic unit
USB 2 B type, USB1.1-compatible.
ETHERNET 10/100 Mbit/s
B type, USB2.0-compatible.
AUX (1/2) Two independent data interfaces.
Can each be used as RS-232 or RS-422/485 design. The RS-422/485 design is
not terminable in the MSC800.
AUX 1 For service purposes.
OUT 4 digital switching outputs, high-side switch.
2 relay outputs, changeover contact for switching protective extra-low voltage
IN 6 digital switching inputs, opto-decoupled.
3 x DC 24 V for supply of external sensors.
With switch S6-1/-2, isolated SGND of the inputs on GND of the MSC800 can be
TRIGGER 4 digital switching inputs, opto-decoupled. TRIG _1 and TRIG_2 are available
redundantly.
3 x DC 24 V for supply of external sensors.
With switch S5, isolated SGND of the inputs on GND of the MSC800 can be
INC 4 digital switching inputs, opto-decoupled. All switching inputs are available
redundantly.
2 x DC 24 V for supply of external sensors.
With switch S4, isolated SGND of the inputs on GND of the MSC800 can be
switched.
HOST (1/2) Two independent data interfaces.
Can each be used as RS-232 or RS-422/485 design. Terminals for HOST 1 are
redundantly available (red 1 to red
4). Data GND isolated from GND of the
MSC800 (GND_13).
The RS-422/485 design is not terminable in the MSC800 with command string.
CAN2 / CAN1 Two independent bus node points. Redundant terminals for each bus node.
CAN2 galvanically isolated from the MSC800 via digital isolator component, has
GND terminals isolated from GND (GND_12).
Termination with double DIP switch S22 and S21.
Two redundant, independent supply inputs.
Tab. 28 MSC800-0000: comments on connections X15 to X1
Further technical information (electrical values, etc.) on the connections can be found from
chapter 5.4.8 on page 64 to chapter 5.4.12 on page 69.