6 COMMISSIONING
94
8026362 / V1-0/2022-03|SICK
SUPPLEMENTARY OPERATING INSTRUCTIONS | VMS4100/5100
Subject to change without notice
In the device tile, click the pen icon next to the IP address.
In the TCP/IP settings window, select the Use the following IP settings option and
define the IP address that is to be used to access the 2D LiDAR sensor in the sensor
network.
Click OK to confirm the entry. The altered IP address is displayed in the device tile.
NOTE! If the configuration PC and the 2D LiDAR sensor are still in the same number
range, the connection to the altered IP address of the 2D LiDAR sensor can be
established directly.
Change the IP address of the configuration PC to the altered address range of the
relevant device.
In the title bar of the device tile, click on the icon with the three dots and select
Remove device entry.
Perform a new device search in SOPAS. The device is found with its new IP address and
displayed in the device list.
Add the device with port 2111 to the SOPAS project.
Changing the
IP address
Procedure in the
event of deviating
address ranges

Table of Contents

Other manuals for SICK VMS4100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SICK VMS4100 and is the answer not in the manual?

SICK VMS4100 Specifications

General IconGeneral
BrandSICK
ModelVMS4100
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals