M90 Fusion Splicer 4-18 Operating Instructions
Splicing Issue 02/97
Attenuation Splice / Fully Automatic
Automatic XYZ, clean,
fuse?
Fully automatic
Automatic
Clean fibers?
Searching fibers?
Automatic XYZ and
fusing?
Attenuation: ### dB
If error message
Cleaning current
13,5 mA
Searching fibers
Automatic Z
level ####
Automatic Z
level ####
XY Video automatic
Prefusion current
### mA
Fusion current
### mA
Fusion time
### s
Attenuation
#,## dB
End
1*
2*
Bad endface
fusing?
Automatic XY
level ####
Automatic XY
level ####
1* The attenuation indicator flashes if fusion is performed after the "Bad endface, fusing?" display.
2* Change required attenuation with button
or and confirm with button .
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com