M90 Fusion Splicer 3-8 Operating Instructions
Parameters and Programs Issue 02/97
Menu Item "Additional Functions"
Menu item "Additional functions" is used to set general parameters.
Options
Submenu "Options" is located in the "Additional Functions" menu (see page 3-4). It
contains common parameters for all programs.
Password Only if activated. See supplementary sheet for explanation.
Splice memory The following splice memory parameters can be set.
1. Splice memory off.
2. Splice memory automatic (presetting): The attenuation values are stored automati-
cally.
3. Splice memory manual: The storage of each attenuation value has to be confirmed
(see page 4-23).
4. Clear splice memory. The entire splice memory is cleared.
Cleaning current The cleaning current can be set between 10.0 - 16.0 mA.
Cleaning time The cleaning time can be set in steps of 0.01 seconds over the range 0.05 - 0.30 sec-
onds.
Battery switch-off
timer
The time interval in battery mode between the last button actuation and the time the
splicer switches off can be set between 2 - 60 minutes.
Altitude correction The setting for site altitude above sea level is used for automatic correction of fusion
current and fusion time.
Off: Setting corresponds to a default site altitude of 550 meters above sea level.
Manual: If you select "Manual“ you must enter the true site altitude above sea level,
accurate to the nearest 10 meters, in the range from 0 to 4000 meters.
Data output
Submenu "Data output" is located in the "Additional functions" menu . It is used to set
all parameters relating to data storage and output.
Baud rate The transmission speed for data output (via the RS 232 interface) can be set.
Possible parameters are:
150, 300, 600, 1200, 2400, 4800 and 9600 baud.
Print splice mem-
ory
If this parameter is set to "Yes", the stored splice values are output via the RS 232 in-
terface.
The splice memory can store 1023 splice values.
Print splicing pa-
rameters
If this parameter is set to "Yes", all splicing parameters are output via the RS 232 inter-
face.