05.05 Function diagrams
SIEMENS AG 6RX1700-0AD76 8-11
SIMOREG DC Master Operating Instructions
Sheet G113 Analog inputs terminals 4/5, 6/7, and 103/104
8
7
564321
i
±10V
u
±20mA
0
1
P701
100%
*
10V =100%
20mA=100%
-1
-1
1
2
3
0
-1
0%
1
0
4
5
6
7
i
±10V
u
±20mA
0
1
P711
100%
*
-1
-1
1
2
3
0
-1
0%
1
0
(i
2mA)
10V =100%
20mA=100%
0
1
-1
-1
1
2
3
0
-1
0%
1
0
M
8 - 270V
103
104
(i
2mA)
1
0
2
1
0
2
1
0
2
1
0
2
P700 (0)
- G113 -
X174
XT
X174
[G127.2]
[G151.1]
P702 (0,00) P703 (0)
P705 (0)
P701.F(100,0)
r001
K0011
P706 (1)
B
P704 (0)
B
K0010
B0050
P707 (12Bit)
P712 (0,00) P713 (0)
P715 (0)
P711.F(100,0)
P710 (0)
r003
K0015
P716 (1)
B
P714 (0)
B
K0014
B0051
P717 (12Bit)
---
-20...+20mA
4 ... 20mA
-10V ... +10V
---
---
-100% ... +100%
-100% ... +100%
0 ... +100%
100%
100%
100%
0%
0%
0%
0
1
2
KxxxxIU
P741.F (60,00)
1ms
K0012
P742 (0,00)
P743 (0)
P745 (0)
r002
K0013
P746 (1)
B
P744 (0)
B
CUD1
CUD1
Power-
Interface
Analog inputs (1)
Hardware-
Smoothing 1ms
Normalization
Offset
Sign reversal
Switch in
analog input
Filter time [ms]
Filtering
Analog select
input
main setpoint
Open circuit
Resolution
Normalization Offset
Sign reversal
Switch in
analog input
Filter time [ms]
Filtering
Signal type
B
Analog select
input 1
Open circuit
Hardware-
Smoothing 1ms
Resolution
Offset
NormalizationSignal type
Normalization
Offset
Sign reversal
Switch in
analog input
Filter time [ms]
Filtering
Analog input
main
actual value
1 = "Fault F046"
1 = "Fault F047"
Signal type
A
D
A
D
A
D

Table of Contents