05.05 Function diagrams
SIEMENS AG 6RX1700-0AD76 8-125
SIMOREG DC Master Operating Instructions
Sheet Z123 OP1S operator panel
87564321
- Z123 -
I
O
Jog
0
123
4
56
789
+/-
Reset
Fault
Run
P
6.0% 0.0V 00
25.00%
25.00%
#
IO
Jog
Reset
<1>
<1>
<1>
B2100
B2107
B2108
B2111
B2113
B2114
B2112
U049.005 U049.004 U049.003
U049.001 U049.002
OP operation. display
1st line on left
FS=19:
display of r019
Motor current act. value
OP operation. display
1st line on right
FS=38:
display of r038
act. armature voltage val.
Active node
(=Bus address P786)
OP operation.display
3rd line
FS=28:
display of r028
Speed setpoint
Reversing key
Raise key
Lower key
Key for the operating
level switchover
0 to 9: Numerical keys
Reset key
Sign key
ON key
OFF key
Inching (Jog) key
ON / OFF1
Acknowledge
Inching 1
Positive direction of rotation
Negative direction of rotation
Raise motor pot.
Lower motor pot.
(B2100 must also be connected
to bit 1 or 2 in control word 1
for OFF2 or OFF3.)
The control commands from the OP1S panel are transferred via word 1 in the USS protocol
and can be wired up to other functions via the binectors below (see also Section 7.2.2).
OP1S operator panel
<1> This key works only when the OP1S
is in the "Operational display" state
Torque direc. 1
LC Display
(4 lines x 16 characters)
OP operation display
4th line
FS=59:
display of r059
Operating state
OP operation.display
2nd line
FS=25:
display of r025
Speed controller act. value

Table of Contents