05.05 Parameter list
SIEMENS AG 6RX1700-0AD76 11-123
SIMOREG DC Master Operating Instructions
PNU
Description Value range
[Unit]
Steps
No. indices
Factory
setting
Type
See
Change
(Access /
Status)
U271
(2271)
*
S00
(B155)
Source for setting value FB 102
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
DT1 element 1 (output = K9223, inverted: K9224)
U272
(2272)
*
S00
(B155)
Source for input quantity FB 103
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U273
(2273)
S00
(B155)
Derivative-action time FB 103
0 to 1000
[ms]
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online
U274
(2274)
S00
(B155)
Filter time FB 103
0 to 1000
[ms]
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online
DT1 element 2 (output = K9225, inverted: K9226)
U275
(2275)
*
S00
(B155)
Source for input quantity FB 104
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U276
(2276)
S00
(B155)
Derivative-action time FB 104
0 to 1000
[ms]
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online
U277
(2277)
S00
(B155)
Filter time FB 104
0 to 1000
[ms]
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online
DT1 element 3 (output = K9227, inverted: K9228)
U278
(2278)
*
S00
(B155)
Source for input quantity FB 105
0 = connector K0000
1 = connector K0001
etc.
All connector
numbers
1
Ind: None
FS=0
Type: L2
P052 = 3
P051 = 40
Offline
U279
(2279)
S00
(B155)
Derivative-action time FB 105
0 to 1000
[ms]
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online
U280
(2280)
S00
(B155)
Filter time FB 105
0 to 1000
[ms]
1
Ind: None
FS=0
Type: O2
P052 = 3
P051 = 40
Online