EasyManua.ls Logo

Siemens SCALANCE XB-200 - Page 87

Siemens SCALANCE XB-200
190 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring with Web Based Management
5.4 The "System" menu
SCALANCE XB-200 Web Based Management
Configuration Manual, 04/2015, C79000-G8976-C360-02
87
E-mail
The device sends an e-mail. This is only possible if the SMTP server is set up and the
"SMTP client" function is enabled.
Trap
The device sends an SNMP trap. This is only possible if "SNMPv1 Traps" is enabled in
"System > Configuration".
Log Table
The device writes an entry in the event log table, see "Information > Log Table"
Syslog
The device writes an entry to the system log server. This is only possible if the system log
server is set up and the "Syslog client" function is enabled.
Fault
The device triggers a fault. The error LED lights up
Steps in configuration
1. Select the check box in the row of the required event. Select the event in the column
under the following actions:
E-mail
Trap
Log table
Syslog
Fault
2. Click the "Set Values" button.