EasyManua.ls Logo

Siemens SIMATIC ET 200pro - Page 129

Siemens SIMATIC ET 200pro
256 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Setting functions
8.5 Motor control
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2015, FW V4.7.3, A5E34257324B AB
129
Example: For a horizontal conveyor, in a first approximation, the moment of inertia depends
on the load.
The relationship between load torque and torque
is saved in the inverter as linear characteristic.
In a positive direction of rotation:
Moment of inertia
J = p5312 × load torque M
L
+
p5313
In a negative direction of rotation:
Moment of inertia
J = p5314 × load torque M
L
+
p5315
You have the following options to determine the characteristic:
You already know the characteristic from other measurements. In this case, you must set
the parameters to known values when commissioning the system.
The inverter iteratively determines the characteristic by performing measurements while
the motor is operational.
Activating the moment of inertia estimator
The moment of inertia estimator is deactivated in the factory setting. p1400.18 = 0,
p1400.20 = 0, p1400.22 = 0.
If you performed the rotating measurement for the motor identification during basic
commissioning, we recommend leaving the moment of inertia estimator deactivated.
Preconditions
You are using a 1FK7 encoderless permanent-field synchronous motor.
You have selected encoderless vector control.
The load torque must be constant whilst the motor accelerates or brakes.
Typical of a constant load torque are conveyor applications and centrifuges, for example.
Fan applications, for example, are not permitted.
The speed setpoint is free from superimposed unwanted signals.
The motor and load are connected to each other with an interference fit.
Drives with slip between the motor shaft and load are not permitted, e.g. as a result of
loose or worn belts.
If the conditions are not met, you must not activate the moment of inertia estimator.