Installation
4.8 Interfaces
SIMATIC ET 200pro FC-2 converter
44 Operating Instructions, 04/2015, FW V4.7.3, A5E34257324B AB
Possible uses for a memory card
The memory card can be used as a parameter memory in the following manner:
Uploading a parameter set to the frequency converter.
Transferring parameters from a memory card when exchanging the converter.
Automatic download of a parameter set to the frequency converter on power-up.
Updating Firmware
Inserting the memory card
The converter must be switchted off and disassembled, before a
memory card can be inserted into the memory card reader.
The label must be facing down with the c
hamfered edge of the
memory card point to the left.
The memory card must be pushed into the card reader slot as far
as it will go; it will make a small click when it is correctly inserted.
Pressing the card again will release it from the memory card rea
d-
er slot.
4.8.1.4
Mini USB interface
Description
The mini USB connector is located at the top-centre of the ET 200pro FC-2 outer casing.
The connector is designed to enable the ET 200pro FC-2 to be connected directly to the
USB port of a PC.
The following components are required to use the Mini USB connection:
A standard Mini USB to standard USB connection cable.
A PC with the one of the following operating systems installed:
Windows XP
Windows 7
The commissioning application STARTER installed on the PC.
The mini USB connector is protected by a plastic screw plug, which
when tightened pres
erves the system's IP67 rating.
Above the mini USB connection there must be a minimum clearance
distance of 50
mm. Otherwise the screw plug cannot be removed.