Technical data
12.5 Electromagnetic compatibility of the converters
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2015, FW V4.7.3, A5E34257324B AB
225
Electromagnetic high
EN 61000-4-3 0.15 MHz … 80 MHz 10 V/m A
Voltage surge EN 61000-4-5 1 kV inverse mode (L-L) A
EN 61000-4-6
0.15 MHz … 80 MHz 10 V/rms
A
High frequency common
80 % AM at 1 kHz
System interruptions and
voltage dips
EN 61000-2-1
100 % voltage dip for 3 ms
30 % voltage dip for 10 ms
60 % voltage dip for 100 ms
95 % voltage dip for 5000 ms
Voltage distortion EN 61000-2-4
10 % THD A
Voltage asymmetry EN 61000-2-4
3 % inverse reactance A
Frequency fluctuation EN 61000-2-4
Rated value 50 Hz or 60 Hz (± 4 %) A
Commutation notches EN 60146-1-1
Class B
A
ET 200pro FC-2 frequency converter in the industrial environment
ET 200pro FC-2 frequency converters with integrated Class A EMC filters are designed for
use in an industrial environment, provided that the permissible cable lengths are used.
Table 12- 5 Use in the industrial environment
EN 61000-6-4, with Class A filter
Installation guidelines for ET 200pro FC-2 frequency converters with integrated EMC filter
● Operation is only permitted for TN line supply systems.
● The converter must be assembled on a grounded plate with a large surface.
● The module rack is to be grounded.
● The maximum length per frequency converter of the shielded power cable is 15 m.