Description
3.2 Spare parts and accessories
SIMATIC ET 200pro FC-2 converter
Operating Instructions, 04/2015, FW V4.7.3, A5E34257324B AB
25
Prefabricated motor cables up to 10 m long are available ex stock for connecting the motor.
Longer lengths up to 15 m can be obtained from our SINAMICS service providers.
Motor cables (discontinued but available as spare parts)
6ES7194-1LC01-0AA0 5.0 m
Using the power jumper connector it is possible for one converter to loop through up to 25 A
from 3AC 400 V to another frequency converter mounted directly alongside. The common
fusing of the primary supply is provided externally.
Sealing cap for power bus
Unused connections without a sealing cap have a degree of protection of only IP20, with a
sealing cap it is IP65.
Sealing caps for power bus
Table 3- 3 Memory cards to back up inverter settings
Memory card without firmware
Memory card with firmware V4.6
Memory card with firmware V4.7
Memory card with firmware V4.7 SP3