ET 200U Distributed I/O Station
EWA 4NEB 812 6087-02b
Figures
5-1 ET 200U(DP Standard): CONFIGURING Screen (1) 5-4. . . . . . . . . . . . . . . . . .
5-2 ET 200U(DP Standard): CONFIGURING screen (2) 5-5. . . . . . . . . . . . . . . . . .
5-3 ET 200U(DP Standard): CONFIGURING Screen (3) 5-6. . . . . . . . . . . . . . . . .
5-4 Example of Process I/O Image with ET 200 5-7. . . . . . . . . . . . . . . . . . . . . . . . .
5-5 Structure of Parameterization Frame 5-16. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-6 Location of the Bank of Switches for Setting the Station Number 5-21. . . . . . .
5-7 SYSTEM START–UP/TEST: MODULE SELECTION Screen 5-24. . . . . . . . . . .
5-8 SYSTEM START–UP/TEST: STATUS/CONTROL Screen 5-25. . . . . . . . . . . . .
5-9 Fault LEDs on the ET 200U Interface Module 5-29. . . . . . . . . . . . . . . . . . . . . . .
5-10 DIAGNOSTICS: OVERVIEW Screen 5-30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-11 INDIVIDUAL DIAGNOSTICS Screen 5-31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-12 Structure of the Diagnostics Word after Request of the Station Status
(Station Status 1 and Station Status 2) 5-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-13 Structure of the Diagnost. Word after Request of the Station Status
(Station Status 3 and Master Address) 5-35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-14 Structure of the Diagnostics Word after Request of the Manufacturer
Identification 5-36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-15 Structure of the Diagnostics Word after Request of Station Diagnostics 5-37.
5-16 Structure of the Diagnostics Word after Request of Module Diagnostics
(Header and Slots 0 to 7) 5-38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-17 Structure of the Diagnostics Word after Request of Module Diagnostics
(Slots 8 to 15 and 16 to 23) 5-39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-18 Structure of the Diagnostics Word after Request of Module Diagnostics
(Slots 24 to 31) 5-39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Tables
5-1 Names of the Type Files for the ET 200U 5-10. . . . . . . . . . . . . . . . . . . . . . . . . . .
5-2 Address IDs for the Modules in an ET 200U(DP Standard) Station 5-10. . . . . .
5-3 Address IDs for the Modules in an ET 200U(DP Standard) Station 5-11. . . . . .
5-4 Address IDs for the Modules in an ET 200U(DP Standard) Station 5-12. . . . . .
5-5 Address IDs for the Modules in an ET 200U(DP Standard) 5-13. . . . . . . . . . . .
5-6 Explanation of Parameters in the DP–IDENTIFIER Field 5-14. . . . . . . . . . . . .
5-7 Meaning of the Parameters in the Parameterization Frame 5-16. . . . . . . . . . . .
5-8 Function of Switch 8 5-22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-9 Resetting Outputs with Load Circuit Turned On 5-27. . . . . . . . . . . . . . . . . . . . . .
5-10 LED Fault Messages on ET 200U Interface Module 5-29. . . . . . . . . . . . . . . . . .
5-11 Diagnostics with STEP 5 5-32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5-12 Structure of Station Diagnostics and Module Diagnostics 5-33. . . . . . . . . . . . . .
ET 200U(DP Standard): Address Assignment, Starting Up, Diagnosing Faults