Siemens SIMATIC S5 ET 200U - Connection of Resistance Thermometers; More than Two Four-Wire Transducer Connections; No Wire Break Detection with 6 ES5 464-8 ME11; Wiring of the Terminal Block

Siemens SIMATIC S5 ET 200U
383 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ET 200U Distributed I/O Station
EWA 4NEB 812 6087-02b
Analog Value Processing
7.1 Analog Input Modules 7-2. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.2 Connecting Current and Voltage Sensors to Analog Input Modules 7-3. . . . .
Voltage Measurement with Isolated / Non–Isolated Thermocouples 7-3. . . . .
Connection of Thermocouples with Compensa–ting Box to Module
464–8MA11/8MA21 7-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Two–Wire Connection of Voltage Sensors 7-5. . . . . . . . . . . . . . . . . . . . . . . . . . .
Two–Wire Connection of Current Sensors 7-6. . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection of Two–Wire Transducers 7-7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection of Four–Wire Transducers 7-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Wiring of the Terminal Block 7-8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
More than Two Four–Wire Transducer Connections 7-8. . . . . . . . . . . . . . . . . .
No Wire Break Detection with 6ES5 464–8ME11 7-8. . . . . . . . . . . . . . . . . . . . .
Connection of Resistance Thermometers 7-9. . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3 Start–Up of Analog Input Modules 7-11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.4 Analog Value Representation of Analog Input Modules 7-16. . . . . . . . . . . . . . . .
7.5 Analog Output Modules 7-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connection of Loads to Analog Output Modules 7-25. . . . . . . . . . . . . . . . . . . . . .
Analog Value Representation of Analog Output Modules 7-27. . . . . . . . . . . . . .
Figures
7-1 Voltage Measuring with Isolated Thermocouples
(6ES5 464–8MA11/8MA21) 7-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-2 Voltage Measuring with Non–Isolated Thermocouples
(6ES5 464–8MA11/8MA21) 7-4. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-3 Two–Wire Connection of Voltage Sensors
(6ES5 464–8MB11, 464–8MC11, 466–8MC11) 7-5. . . . . . . . . . . . . . . . . . . . . . .
7-4 Two–Wire Connection of Current Sensors (6ES5 464–8MD11) 7-6. . . . . . . . .
7-5 Connection of Two–Wire Transducers (6ES5 464–8ME11) 7-7. . . . . . . . . . . .
7-6 Connection of Four–Wire Transducers (6ES5 464–8ME11) 7-8. . . . . . . . . . . .
7-7 Wiring Method for PT 100 (6ES5 464–8MF11/8MF21) 7-9. . . . . . . . . . . . . . . .
7-8 Wiring Possibilities for Input Modules (6ES5 464–8MF11) 7-10. . . . . . . . . . . . .
7-9 Load Connection via a Four–Wire Circuit (6ES5 470–8MA11,
6ES5 470–8MD11) 7-26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7-10 Connection via a Two–Wire Circuit
(6ES5 470–8MB11, 6ES5 470–8MC11) 7-27. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7

Table of Contents

Related product manuals