5.2.3 Using the SYSTEM START–UP/TEST Screen for an ET 200U(DP
Standard) Slave Station
For starting up an ET 200U slave station, COM ET 200 provides two screens.
Select one slot in the SYSTEM START–UP/TEST: MODULE SELECTION
screen. Then call up the SYSTEM START–UP/TEST: STATUS/CONTROL
screen.
Proceed as follows:
1. Using the cursor control keys and <F5> (SELECT), select one slot (one
module) whose input data you want to evaluate or whose outputs you
want to force.
Result: The selected module is marked with an asterisk “*”. Pressing
<F5> (SELECT) a second time cancels the selection.
SELECT ENTER EXIT
F2 F3 F4 F5 F6 F7 F8F1
Station number: 4
Program file selected: TEST@@ET.200
SIMATIC S5 / COM ET 200
SYSTEM START–UP / TEST: MODULE SELECTION
Station type: ET 200U–DP
Station name: PRESS
Configuration:
0.
016
1.
2.
3.* 4. 5.
6.
7.
032
8.
9.
10.
11. 12. 13.
14.
15.
16.
17.
18.
19. 20. 21.
22.
23.
24.
25.
26.
27. 28. 29.
30.
31.
097 243 243
Figure 5-7 SYSTEM START–UP/TEST: MODULE SELECTION Screen
ET 200U(DP Standard): AddressAssignm.,Starting–Up, DiagnosingFaultsUsing COM ET 200