Online Settings and Displays
17.2 Command
SIMOCODE PRO V PN FDI
144 Programming and Operating Manual, 05/2020, A5E44499659002A/RS-AA/001
Command
Meaning
Delete initialization module data With this command:
All contents of the initialization module are deleted
The initialization module is reset to the delivery
state.
SIMOCODE pro signals the successful deletion with
the event "Initialization module deleted".
In the event of a startup with an empty initialization
module, the basic unit signals "Trip -
Parameterization". The "General Fault" LED of the
basic unit flashes red.
Reparameterization of the device, e.g., with Device
Integration Manager, writes valid parameters to the
basic unit and the initialization module again. You can
then acknowledge the event.
Restart - Cold Start
Re-start: Initializing SIMOCODE pro. New run-up.
Basic factory default settings All parameters are reset to the basic factory default
settings. Only possible if no password protection exists
or the password is known to the user.
Set time (= PC time) If an NTP server address has not been configured or a
server was not found on the network, you can set the
time of day here.
If a valid time of day is available (either synchronized
by NTP or set via Device Integration Manager), the
entries in the error buffer/error protocol (i.e. log) will be
additionally displayed with the time of day. In addition,
the "Clock set (NTP)" and "Clock synchronized (NTP)"
messages are displayed.
If you would like to set up the time in device to UTC
time (recommended) please set first +/- offset in NTP
Time shift parameter in minutes respective to current
time zone and then upload the data to the device.
Test Carry out test function. Same function
as"TEST/RESET" button on the basic device and
operator panel.
Reset Carry out reset. Acknowledging errors.Same function
as "TEST/RESET" button on the basic device and
operator panel.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOCODE 3UF and is the answer not in the manual?

Siemens SIMOCODE 3UF Specifications

General IconGeneral
BrandSiemens
ModelSIMOCODE 3UF
CategoryControl Systems
LanguageEnglish

Related product manuals