Standard Functions
12.4 Operational Protection OFF (OPO)
SIMOCODE PRO V PN FDI
94 Programming and Operating Manual, 05/2020, A5E44499659002A/RS-AA/001
Safety information
Note
A "Trip
- Operational Protection Off (OPO)" fault message is not generated if the "OPO"
command attempts to run the Positioner to the end
position in which it is already in, or to
which it is heading.
Note
No other control command (counter command or stop command) is carried out while
"Operational Protection Off (OPO)" is active.
Note
The "Trip
- Operation Protection Off (OPO)" fault message must be acknowledged using the
open or closed control command, depending on the present "OPO" end position.
Note
Acknowledgement is carried out even if the desired end position has not yet been reached.
Note
The fault message is
available as diagnosis via PROFINET.
Response to other Control Functions:
For other control functions, the following scenarios can be differentiated between for OPO:
Motor in operation: The motor is switched off with a "Trip - Operational Protection Off
(OPO)" fault.
The motor is off. Initially no fault. The "Trip - Operational Protection Off (OPO)" fault only
occurs when an "ON Command" is issued.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens SIMOCODE 3UF and is the answer not in the manual?

Siemens SIMOCODE 3UF Specifications

General IconGeneral
BrandSiemens
ModelSIMOCODE 3UF
CategoryControl Systems
LanguageEnglish

Related product manuals