SIMPRO-100
SIMPRO-PC Compatibility Features
D
PRIM-2400C 191
FF Scale factor type
0000 Scale factor offset in Fast Meter message
494300000000 Analog channel name (IC)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
494E00000000 Analog channel name (IN)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
334932000000 Analog channel name (3I2)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
25556E62616C Analog channel name (%Unbal)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
465245510000 Analog channel name (Freq)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
25544845524D Analog channel name (%Therm)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
25464C410000 Analog channel name (%FLA)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
If the Relay is Equipped with Voltage Inputs
564142000000 Analog channel name (VAB)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
564243000000 Analog channel name (VBC)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
564341000000 Analog channel name (VCA)
Data Description
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
564700000000 Analog channel name (VG)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
335632000000 Analog channel name (3V2)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
6B5700000000 Analog channel name (kW)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
485000000000 Analog channel name (HP)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
6B5641000000 Analog channel name (kVAR)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
706600000000 Analog channel name (pf)
01 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
If the Relay is Equipped with Internal or External RTD
Inputs
574447000000 Analog channel name (WDG)
[Hottest Winding RTD Temp.]
00 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
425247000000 Analog channel name (BRG)
[Hottest Bearing RTD Temp.]
00 Analog channel type
FF Scale factor type
0000 Scale factor offset in Fast Meter message
414D42000000 Analog channel name (AMB)
[Ambient RTD Temp.]
Data Description