Command lists
10.2 Command lists
SIWAREX WP231
142 Manual, 07/2014, A5E31238908A-02
715 G process value (no write protec-
tion)
Display gross process weight on main display,
only permitted if OIML R76 is not set as the
regulation code (main display and SecureDis-
play)
P
716 G process value after filter 2 Display gross process weight (commissioning)
on main display, only permitted if OIML R76 is
not set as the regulation code (main display
and SecureDisplay)
P
801 Display currently set calibration
regulation /country code
Display currently set calibration regulation
temporarily on the main display (main display
and SecureDisplay), for duration of 5 s
802 Display weighing range data Display weighing range data (min., max., digit
step) in the legal trade display SecureDisplay
(for duration of 10 s)
860 Hide display Hides the legal trade display SecureDisplay
861 Legal trade display for variant 1 Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
862 Legal trade display for variant 2 Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
863 Legal trade display for variant 3 Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
864 Legal trade display for variant 4 Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
865 Legal trade display for variant 5 Acts on the legal trade display SecureDisplay.
Enables version 1 for display size and position
according to DisplayCali.xml file
870 Display smallest representation of
legal trade display
Shows the smallest possible display of the
SecureDisplay according to parameter "Min.
zoom factor Display%" in DR3
871 Display current serial number Display serial number of SIWAREX temporarily
on the main display and SecureDisplay, for
duration of 5 s
875 Display FW version Display current firmware version of module on
SecureDisplay
876 Display SecureDisplay software
version
881 Display first logbook entry The first logbook entry is displayed on the
SecureDisplay.
882 Display last logbook entry The last logbook entry is displayed on the
SecureDisplay.
883 Display reading of previous entry The logbook entry prior to the last read entry is
displayed on the SecureDisplay.
884 Display reading of subsequent
entry
The logbook entry after the last read entry is
displayed on the SecureDisplay.
891 Display log entry (DS46) The log entry requested in DS45 is displayed
on the SecureDisplay, for duration of 10 s.
Reserve
Reserve
Reserve