All relevant persons (e.g., operating personnel,
supervisors) must be informed of the activity
prior to the start of work. Precautionary
operational measures / work instructions
must be observed.
o Take appropriate measures to ensure
that moving/detached parts are immo-
bilized during the work and that no body
parts can be pinched by unintended
movements.
o Assemble the product only outside the
operating range of moving parts, at an
adequate distance from sources of heat
or cold.
o Prior to performing work, the product
and the machine/system in which the
product is integrated must be de-ener-
gized and depressurized and secured
against unauthorized activation.
o All work on electrical components may be
performed only with voltage-insulated
tools.
o Fuses must not be bridged. Always replace
fuses with fuses of the same type.
o Ensure proper grounding of the product.
o Drill required holes only on non-critical,
non-load bearing parts.
o Other units of the machine/the vehicle
must not be damaged or impaired in their
function by the installation of the centra-
lized lubrication system.
o No parts of the centralized lubrication
device may be subjected to torsion, shear,
or bending.
o Use suitable lifting gear when working
with heavy parts.
o Avoid mixing up/incorrectly assembling
disassembled parts. Label parts.
1.7 Assembly/maintenance/malfunction/decommissioning/disposal
1. Safety instructions
1.8 Intended use
Gear pump units of SKF series MKU, MKF,
and MKL are for supplying centralized lu-
brication systems with lubricant and are
intended for use in centralized lubrication
systems. They feed mineral and synthetic
oils and greases that are compatible with
plastic and NBR elastomers.
Gear pump units of product series MKU
and MKL are suitable for supplying oil with
a viscosity range from 20 to 1500 mm²/s.
Gear pump units of product series MKF are
for supplying fluid greases of NLGI grades
000 and 00.
The permissible operating temperature ran-
ge is +10 to +40°C on all three series.
The Technical Data in Chapter 4 as well as
Chapter 10 must be observed.
Only media approved for the gear pump
units may be used. Unsuitable media may
result in pump unit failure and potentially
severe bodily injury or death and property
damage.
The use of synthetic and biodegradable oils
or greases requires prior approval from SKF.

Table of Contents

Other manuals for SKF MKU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF MKU Series and is the answer not in the manual?

SKF MKU Series Specifications

General IconGeneral
BrandSKF
ModelMKU Series
CategoryWater Pump
LanguageEnglish

Related product manuals