26
EN
3. Overview
Electrical connection
1 = 1 cable gland, 1 square connector
Pressure gauge
0 = Without pressure gauge
1 = With pressure gauge
3.5 Order code for MKL gear pump units
Order code
M K L – 1 F C 1 0 0 0 +
Product series MKx
L = Oil + air system
Delivery rate
1 = 0.1 l/min • • –
2 = 0.2 l/min • • •
5 = 0.5 l/min • • •
Delivery rate
Lubricant reservoir, control unit
Lubricant reservoir 2 3 4
3-liter
plastic
3-liter
metal
6-liter
plastic
Control unit
1) Only possible with delivery rate 0.1- and 0.2 l/min.
Lubricant reservoir
Control unit
Voltage code
Voltage Frequency Control unit
924
1)
24 V DC – A, B, E
428 230 V AC
50/60 Hz A, B, C, D, E
429 115 V AC
Monitoring
Pressure gauge
Electrical connection
Voltage code 24 VDC, 320 VAC, 115 V AC
F = Control unit IG54-20-S4
Monitoring
C = Monitoring unit with fill level switch (NC contact) and
pressure switch 20 bar (NO-contact)