9.3 Commissioning, product, and system malfunctions
Malfunction Cause Remedy
Motor fails to start
when the operating
voltage is applied
o No operating voltage on motor
Check mains connection
Check mains plug/cable and connect properly if necessary
Check operating voltage on motor
Check fuse
Check motor circuit breaker
o Pump jammed
Measure motor current If current is impermissibly high:
Dismantle pump, crank by hand:
If resistance is high, replace the pump.
o Motor jammed
Measure motor current If current is impermissibly high:
Dismantle motor, crank by hand:
If resistance is high, replace the motor.
Motor runs with
difficulty and at a
low speed
o Sluggish pump
Measure motor current If current is impermissibly high:
Dismantle pump, crank by hand:
If resistance is high, replace the pump.
Motor runs with
difficulty and at a
low speed
o Sluggish motor
Measure motor current If current is impermissibly high:
Dismantle motor, crank by hand:
If resistance is high, replace the motor.
o Unsuitable lubricant (see technical data) Remove lubricant from entire system and dispose of lubricant in
the proper manner; fill system with suitable lubricant
o Pressure too high, pressure-regulating
valve is jammed or defective
Check pressure-regulating valve and replace if necessary