Malfunction Cause Remedy
Motor runs with
difficulty and at a low
speed
o Ambient temperature too low
(see technical data) Increase ambient temperature
Pump does not convey
lubricant; no pressure
build-up
o Pump jammed
Measure motor current If current is impermissibly high:
Dismantle pump, crank by hand:
If resistance is high, replace the pump.
o Motor jammed
Measure motor current If current is impermissibly high:
Dismantle motor, crank by hand:
If resistance is high, replace the motor.
o
Incorrect rotational direction of motor
Check pressure-regulating valve to make sure that opening pres-
sure is correct and that there is no contamination or damage
If opening pressure is incorrect or if the pressure-regulating valve
is damaged, replace the valve. Only use original SKF spare parts.
If contaminated, clean the pressure-regulating valve
No pressure build up in
the main line
o Air in the main line
o Main line leaky/broken
Vent main line
Repair main line
o Pressure-regulating valve does not
close
Check pressure-regulating valve to make sure that opening pres-
sure is correct and that there is no contamination or damage
If opening pressure is incorrect or if the pressure-regulating valve
is damaged, replace the valve Only use original SKF spare parts.
If contaminated, clean the pressure-regulating valve
EN
9. Malfunctions, causes, and remedies

Table of Contents

Other manuals for SKF MKU Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the SKF MKU Series and is the answer not in the manual?

SKF MKU Series Specifications

General IconGeneral
BrandSKF
ModelMKU Series
CategoryWater Pump
LanguageEnglish

Related product manuals