EasyManua.ls Logo

SKF MKU Series - Page 93

SKF MKU Series
102 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
93
9
Malfunction Cause Remedy
Motor runs with
difficulty and at a low
speed
o Ambient temperature too low
(see technical data) Increase ambient temperature
Pump does not convey
lubricant; no pressure
build-up
o Pump jammed
Measure motor current If current is impermissibly high:
Dismantle pump, crank by hand:
If resistance is high, replace the pump.
o Motor jammed
Measure motor current If current is impermissibly high:
Dismantle motor, crank by hand:
If resistance is high, replace the motor.
o
Incorrect rotational direction of motor
Check pressure-regulating valve to make sure that opening pres-
sure is correct and that there is no contamination or damage
If opening pressure is incorrect or if the pressure-regulating valve
is damaged, replace the valve. Only use original SKF spare parts.
If contaminated, clean the pressure-regulating valve
No pressure build up in
the main line
o Air in the main line
o Main line leaky/broken
Vent main line
Repair main line
o Pressure-regulating valve does not
close
Check pressure-regulating valve to make sure that opening pres-
sure is correct and that there is no contamination or damage
If opening pressure is incorrect or if the pressure-regulating valve
is damaged, replace the valve Only use original SKF spare parts.
If contaminated, clean the pressure-regulating valve
EN
9. Malfunctions, causes, and remedies

Table of Contents

Other manuals for SKF MKU Series

Related product manuals