Fill the gear pump unit with lubricant via
the filler socket (1)
Remove the lubricant line at the end of
the first distributor (2)
Allow the pump to run until lubricant
without bubbles discharges
Mount the lubrication line
Repeat the venting procedure at the
following distributor
Allow pump to run until oil can be seen
discharging at all lubrication points
The process of venting the centralized
lubrication system can be facilitated by:
o Opening the ends of the main pipes until
lubricant without bubbles is discharged
o Filling long pipe sections before connecting
to the lubrication points
1
Single-line centralized lubrication system, Fig. 38
Single-line
distributor
Lubrication point
2
4.15 Venting a MKU/MKF/MKL centralized lubrication system