87
7
7.3 Recommissioning
The lubricant may only be fed without bubbles.
The lubricant reservoir must be filled with
clean lubricant. The product is then operated
until lubricant without bubbles is discharged
at all lubrication points.
Air pockets in the lubricant adversely affect
the function of the device and impair the
reliability of lubricant delivery, which can
result in damage to the bearings requiring
lubrication.
EN
7.4 Shutdown and disposal
If the product is to be shut down permanently,
observe the legal requirements for disposal
of contaminated parts/equipment.
The product can also be returned to SKF
Lubrication Systems Germany GmbH for
disposal, in which case the customer is
responsible for reimbursing the costs incurred.
The parts are recyclable.
Note
Environmental pollution
Lubrication lines must always
be free of leaks. Lubricants can
contaminate soil and waterways.
Lubricants must be used and
disposed of properly. Observe the
local regulations and laws regar-
ding the disposal of lubricants.
Dispose of lubricant drums in an
environmentally friendly way
EWC-CODE: 15 01 10
7. Operation/decommissioning and disposal