29
4
4.3 Assembly drawing with minimum installation dimensions
4.3.1 MKU/MKF gear pump units with 2-liter plastic reservoir for oil and fluid grease
MKU/MKF gear pump u
nit with 2-lit
er
plastic r
eservoir for oil and fl
uid
gre
ase,
Fig.
3
Clearance for lid removal
13
Assembly holes
Minimum mounting dimensions
A = width: 350 mm
B = height: 380 mm
C = depth: 140 mm
A
C
B
Recommended fastening hardware:
o Hexagon head bolts (2x) acc. to
ISO 4017-M8x25-8.8
o Washers (4x) acc. to
ISO 7090- 8-200-HV
o Hexagon nuts (2x) acc. to
ISO 4032-M8-8
Tightening torque: 25 Nm