REMOTE BUS INTERFACE: RS-232
70
Command
Name
Test
Types
Value
ELINE
{1|2|3|4|5|6|7|8}
ELINE?
Edit Line Fault
Condition
LLT
1=Open Neutral, Normal
Polarity, Open Ground
2=Open Neutral, Reverse
Polarity, Open Ground
3=Open Neutral, Normal
Polarity, Closed Ground
4=Open Neutral, Reverse
Polarity, Closed Ground
5=Closed Neutral, Normal
Polarity, Open Ground
6=Closed Neutral, Reverse
Polarity, Open Ground
7=Closed Neutral, Normal
Polarity, Closed Ground
8=Closed Neutral, Reverse
Polarity, Closed Ground
EM
{0|1|2|3|4}
EM?
Edit Meas-Device
LLT
0=MD-A
1=MD-B
2=MD-C
3=External
4=Frequency Check
EO < value >
EO?
Edit Offset
GND
0 - 100mΩ
EP < value >
EP?
Edit Probe Config.
LLT
0=Ground to Line
1=Ground to Neutral
EPFH < value >
EPFH?
Edit PF-HI
RUN
0.000 - 1.000
EPFL < value >
EPFL?
Edit PF-LO
RUN
0.000 - 1.000
EPOH < value >
EPOH?
Edit Power-HI
RUN
0 - 8400W
EPOL < value >
EPOL?
Edit Power-LO
RUN
0 - 8400W
ERU < value>
ERU?
Edit Ramp-Up
ACW
DCW
0.1 - 999.9s
EV <value>
EV?
Edit Voltage
ACW
DCW
IR
1 3.5kV
1 4.0kV
100 - 1000V
EVH < value >
EVH?
Edit Voltage-Hi
RUN
LLT
0.0 - 277.0V
EVL < value >
EVL?
Edit Voltage-Lo
RUN
LLT
0.0 - 277.0V