HBM: public
%=90, FSMax = 100, FSMin = -100. The output is set to logic TRUE if value >
90 or if value < -90
%=90, FSMax = 200, FSMin = -100. The output is set to logic true if value > 180
or if value < -90
Log Alarms
This option will generate Log file messages when channels are over range. Only one
FSMax over range and one FSMin over range message will be generated for each
channel over the duration of the test run. Normally, this option is enabled to allow the
user to determine which channel(s) caused the output channel to be set to true.
See also Data Types “Computed Channel” on page 192.
7.5.7 Valid Data Gate
The Valid Data Gate channel generates a logical channel data stream on a sample by
sample basis marking samples containing invalid data. The output sample is TRUE if
and only if the data samples for all input channels are valid; otherwise, the output
sample is FALSE. Use the Valid Data Gate channel by itself or in conjunction with other
logical channels as a gate trigger for DataModes to eliminate any invalid data samples.
Input Channel
The only channels that currently use invalid flags are vehicle bus, serial bus, GPS and
temperature channels. All data types are supported.
Output Data Type
The output channel data type is 8-bit unsigned (logical).