12.6.2 Transducer Cable for J1708 Interface
The following table lists the pinouts for the SAC-TRAN-MP when used with the J1708
interface.
NOTE
Always provide the +12 volt REF voltage for the J1708 module to function.
12.6.3 Transducer Cable for CAN/SWC Interface
The following table lists the pinouts for the SAC-TRAN-MP cable when used with the
CAN/SWC interface
NOTE
Connection to both the SWC pin and the CAN pins is allowed, but only one source can
be used at any given time.
NOTE
SWC operation is restricted to the EMCAN.04 version of the CAN VBM.
NOTE
Always provide the +12 volt REF voltage for the SWC interface.
Function Pin Wire Color
VPW_bus 2 White
AGnd 3 bare wire
+12 V REF 5 Red
Function Pin Wire Color
J1708_A 2 White
AGnd 3 bare wire
+12 V REF 5 Red
J1708_B 6 Green