67MS 441, MS 441 C
: Take out screw (arrow).
– Remove and examine ground
wire (1) and cable guide (2),
replace if necessary.
219RA402 TG
2
1
: Fit ground wire (1) and cable
guide (2) and insert screw.
1
2
219RA527 TG
– Support eyelet at supporting
rib (1).
: Insert screw (2) and tighten it
down.
219RA620 TG
3
1
2
: Push connector (3) onto the
terminal socket so that it is out of
line in counterclockwise direction
– the loop (arrow) must face the
housing wall.
: Wiring harness and short circuit
wire must lie flat in the guides
(arrows).
– Reassemble all other parts in the
reverse sequence.
– Tightening torques, b 3.5.
219RA403 TG
– Remove fan housing,
b 10.2.
: Take out screws (arrows).
– Slide pre-separator (1) up slightly
and take it out.
219RA368 TG
1
: Pull out duct base (1).
– Examine pre-separator (2) and
duct base (1) and replace if
necessary.
219RA379 TG
2
1
9.7 Pre-separator