Operation and Maintenance Manual Model 7AA Wafer Grinder
10 - 4 Version 1.2 - April 18, 1996
incorrect thickness measurement chuck not centered with probe
probe not zeroed correctly
defective probe electronics
chuck stroke time not correct
elevator not operating other elevator not at top
elevator disconnected
cassette not sensed
force grinding machine not initialized properly
excessive feed rate parameter
incorrect wheel wear compensation
wheels require dressing
insufficient coolant flow